Home  |  Contact Us  |  Download  |  中文版
Home About Us News Products Network Download Case Feedback Recruitment Contact
Loading...
    Column Navigation
Electro-Mechanical UTM
Hydraulic UTM
Hydrauic Compression
Impact Tester
Fatigue Testing Machine
Torsion Testing Machine
Hardness Tester
NDT Equipment
Metallographic Sample Preparation
Friction & Wear Testing
High Temp. Vacuum Furnaces
Plastic & Rubber Instruments
Other Products
    Contact Us
Addr: 1044 Building No. 5, Zhumuchang Xiaoqu, Yongshun Town, Tongzhou District, 101101 Beijing P.R. China
Tel: 086-10-51249519
Fax: 086-10-80115555 ext. 771703
E-mail: sinofound@126.com, dsteve@163.com
Website: http://www.sinofound.com
Your Current Location:Home > Products > Plastic & Rubber Instruments > Heat Deflection Temperature and VICAT Softening Point Apparatus
Product Name:Heat Deflection Temperature and VICAT Softening Point Apparatus
Product Detailed:

Features & Applications

This apparatus is used to determine Heating deflection temperature under load and Vicat softening point of plastic, rubber or other thermoplastic materials. It is widely adopted by petrol-chemical industrial enterprises, scientific research centre and university laboratories for new materials research and development.

The apparatus fully conforms to the technical requirements of following standards: ISO 75(E), ISO 306(E), ASTM D 648, ASTM D 1525, GB/T1633, GB/T1634, GB/T8802, and DIN 53461 

l  Upper limit temperature can be set: when test temperature reach upper limit temperature, the apparatus shall automatically stop heating.

l  Upper limit temperature, heating up rate and real temperature and test result temperature is digital display (by computer screen).

l  Automatic record heating deflection temperature, vicat softening temperature and sound alarm.

l  The system shall automatically stop heating after the test is over, and print the test report as well as test curves.

 Main Technical Specifications

Temperature range                   room temperature--300℃

Heat up rate                         120℃/h (12±1℃/6min)   50℃/h (5±0.5℃/6min)

Temperature accuracy                 ±1℃

Temperature resolution               0.1℃

Deflection measuring range           0-1.000mm

Deflection accuracy                   0.001mm

Load rod and press head weight          68±2g

Number of station                       4

Heating power                                 4.0 Kw

Heating medium                      methyl silicon oil or transformer oil (25 L)

Power supply                        4KW, 220V, 50Hz

Cooling mode                        faster water cooling fully or natural cooling

Overall dimensions(L x W x H)       800 x 600 x 700mm

Net weight                         80Kg   

 

Standard Configuration

1. Mainframe                                     01 set

2. Sample frame station                            04 Nos

3. Weight (as per weights list)                      01 set

4. Rod with VICAT testing                          04 sets

5. Press head with Heat Deflection testing           04 sets

6. Mainframe power cable                         01 pc

7. Communication cable                                               01 pc

8. Computer system (Dell latest brand, Memory 1.0GB)            01 Set

 

Weights List

Code

A

B

C

D

E

F

G

H

I

J

W

K

Mass

(g)

2000

1000

932

500

200

100

50

20

10

5

2

1

Qty.

3

6

1

3

6

3

3

6

3

3

6

3

Links:
Addr:1044 Building No. 5, Zhumuchang Xiaoqu, Yongshun Town, Tongzhou District, 101101 Beijing P.R. China  Tel:086-10-51249519    
CopyRight © 2019 Beijing Sinofound Co., Ltd.  All rights reserved  京ICP备14025768号-1